UL 3656 ESUN HALOGEN-FREE CROSS-LINKED WIRE Halogen-free cross-linked wire
- Description
-
Printed text:
AWM 3656 XLPE E237675 VW-1 150℃ 300V ( ) AWG RISHUN c
AWM I A FT1 150℃ 300V ( ) AWG LF Instructions
► Rated temperature: 150℃ Rated voltage: 300V
► Standards: UL758, UL1581, UL255
► The conductor uses 40-10 AWG single-strand or stranded bare copper or tinned copper wire.
►Cross-linked polyethylene insulation
► Uniform insulation thickness for easy stripping and cutting.
►ULVW-1 and cUL FT1 flame-retardant testsApplication
For internal wiring in electronic and electrical equipment
Cores
Number of coresConductor
ConductorInsulated
InsulationWrap-around layer
Spiral Shield
Twisted shieldingJacket
SheathMaximum
Resistance
At 20℃
Maximum conductor resistance
Ω/kmAWG
Line numberConstruction
StructureDia.
(mm)Thick
Insulation thickness
(mm)Dia.
(mm)material
MaterialsNo./mm
Number of wires / Wire diameterThick.
Standard thickness
(mm)Dia.
(mm)2
30
7/0.102
0.30
0.25
0.80
Aluminum foil
Al-Myiar
(Optional)45/0.10
0.38
2.65
28
7/0.127
0.38
0.25
0.90
50/0.10
0.38
2.85
26
7 divided by 0.16
0.48
0.25
1.00
55/0.10
0.38
3.06
24
11/0.16
0.61
0.25
1.10
61/0.10
0.38
3.25
22
17/0.16
0.76
0.25
1.30
71/0.10
0.38
3.65
20
21/0.178
0.94
0.25
1.50
82/0.10
0.38
4.05
18
34/0.178
1.20
0.25
1.80
92/0.10
0.38
4.65
3
30
7/0.102
0.30
0.25
0.80
Aluminum foil
Al-Myiar
(Optional)48/0.10
0.38
3.00
28
7/0.127
0.38
0.25
0.90
54/0.10
0.38
3.20
26
7 divided by 0.16
0.48
0.25
1.00
59/0.10
0.38
3.40
24
11/0.16
0.61
0.25
1.10
65/0.10
0.38
3.65
22
17/0.16
0.76
0.25
1.30
76/0.10
0.38
4.05
20
21/0.178
0.94
0.25
1.50
88/0.10
0.38
4.50
18
34/0.178
1.20
0.25
1.80
105/0.10
0.38
5.15
4
30
7/0.102
0.30
0.25
0.80
Aluminum foil
Al-Myiar
(Optional)53/0.10
0.38
3.00
28
7/0.127
0.38
0.25
0.90
60/0.10
0.38
3.20
26
7 divided by 0.16
0.48
0.25
1.00
66/0.10
0.38
3.40
24
11/0.16
0.61
0.25
1.10
73/0.10
0.38
3.65
22
17/0.16
0.76
0.25
1.30
85/0.10
0.38
4.10
20
21/0.178
0.94
0.25
1.50
98/0.10
0.38
4.50
18
34/0.178
1.20
0.25
1.80
117/0.10
0.38
5.15
5
30
7/0.102
0.30
0.25
0.80
Aluminum foil
Al-Myiar
(Optional)60/0.10
0.38
3.20
28
7/0.127
0.38
0.25
0.90
67/0.10
0.38
3.45
26
7 divided by 0.16
0.48
0.25
1.00
74/0.10
0.38
3.70
24
11/0.16
0.61
0.25
1.10
81/0.10
0.38
3.95
22
17/0.16
0.76
0.25
1.30
95/0.10
0.38
4.40
20
21/0.178
0.94
0.25
1.50
109/0.10
0.38
4.90
18
34/0.178
1.20
0.25
1.80
131/0.10
0.38
5.60
6
30
7/0.102
0.30
0.25
0.80
Aluminum foil
Al-Myiar
(Optional)66/0.10
0.38
3.45
28
7/0.127
0.38
0.25
0.90
74/0.10
0.38
3.70
26
7 divided by 0.16
0.48
0.25
1.00
82/0.10
0.38
4.00
24
11/0.16
0.61
0.25
1.10
90/0.10
0.38
4.25
22
17/0.16
0.76
0.25
1.30
105/0.10
0.38
4.80
20
21/0.178
0.94
0.25
1.50
121/0.10
0.38
5.35
7
30
7/0.102
0.30
0.25
0.80
Aluminum foil
Al-Myiar
(Optional)66/0.10
0.38
3.50
28
7/0.127
0.38
0.25
0.90
74/0.10
0.38
3.80
26
7 divided by 0.16
0.48
0.25
1.00
82/0.10
0.38
4.10
24
11/0.16
0.61
0.25
1.10
90/0.10
0.38
4.35
22
17/0.16
0.76
0.25
1.30
105/0.10
0.38
4.90
20
21/0.178
0.94
0.25
1.50
121/0.10
0.38
5.50
The above wire data is for reference only and shall not be used as the basis for formal design. Product specifications shall be subject to those confirmed by both parties in the specification document!
key word:
UL 3656 ESUN HALOGEN-FREE CROSS-LINKED WIRE Halogen-free cross-linked wire