- Description
-
Printed text: CCC A067211 60227 IEC 52(RVV) 300/300V ( )mm² GB/T 5023.5-2008 Taizhou Rishun Electrical Development Co., Ltd.
Instructions
► The conductor uses 0.5–0.75 mm² stranded bare copper.
► Passed the GB/T 18380.12 combustion test
► Possesses properties such as acid and alkali resistance, oil resistance, moisture resistance, and mold resistance.Application
Electrical lead wires, power cords
Type Number of Cores Conductor – conductor Insulation Jacket sheath Maximum Resistance at 20℃ Maximum Conductor Resistance Ω/km Sectional-Cross
Aream Cross-sectional area mm²construction structure Dia. Outer diameter mm Nom. Thick. Standard thickness mm Dia. Outer diameter mm Nom. Thick. Standard thickness mm Dia. Outer diameter mm 2 0.5 16/0.20 0.92 0.54 2 0.65 5.3 39 28 divided by 0.15 0.92 3.30 × 5.30 0.75 24/0.20 1.13 0.54 2.2 0.65 5.7 26 42/0.15 1.13 3.50 × 5.70 3 0.5 16/0.20 0.92 0.54 2 0.65 5.6 39 28 divided by 0.15 0.92 0.75 24/0.20 1.13 0.54 2.2 0.65 6.1 26 42/0.15 1.13
key word:
60227 IEC 52 (RVV) connecting cable
Recommended Products