• Description
  • Instructions
    ► Rated voltage 600V, rated temperature 200℃
    ►Flame Retardancy UL: VW-1
    ► At high temperatures and high frequencies, both the dielectric constant and dielectric loss are low.
    ► Excellent heat resistance, oil resistance, low-temperature resistance, and chemical resistance.
     
    Application
    Internal wiring of electronic machines and small electrical appliances
    For applications with high bending performance requirements, such as mobile phones and digital videos, etc. Notes
    1. Electrical Characteristics
    Minimum insulation resistance (at 20℃): 1000 MΩ/km
    Withstand Voltage: A.C. 2000V/1min.

     

    UL
    STYLE NO.
    Insulation
    Materials
    Rated (RATING) Conductor (tin-plated soft copper wire) CONDUCTOR
    (Tinned Annealed Copper Wire)
    Insulator Maximum conductor resistance
    MAX.
    CONDUCTOR
    RESISTANCE
    (20℃)
    (Ω / km)
    Dielectric withstand voltage
    DIELECTRIC
    STRENGTH
    V(AC)/min
    Temperature
    TEMP.
    (℃)
    Voltage
    VOLT
    (V)
    SIZE
    (AWG)
    constitute
    N/mm
    Outer diameter
    NOM.
    DIA
    (mm)
    Thick insulation
    NOM.
    THICK.
    (mm)
    Outer diameter
    NOM.
    DIA.
    (mm)
    UL10308 FEP 200 600 30 7/0.102 0.30 0.25 0.80 354.33 2000
    28 7/0.127 0.38 0.25 0.90 223.75
    26 7/0.160 0.48 0.25 1.00 139.76
    24 7/0.203 0.60 0.25 1.10 85.96
    22 7/0.254 0.76 0.25 1.30 54.79
    20 21/0.178 0.96 0.25 1.50 38.58
    18 34/0.178 1.20 0.25 1.70 22.98
    16 26/0.254 1.50 0.25 2.00 15.06

key word: