• Description
  • Instructions 
    ► Rated voltage: 125V, rated temperature: 105℃ 
    ►Flame Retardancy UL: VW-1 
    ► Excellent electrical and mechanical properties 
    ► Excellent low-temperature resistance

     
    Application 
    Internal wiring of electronic machines and small electrical appliances 
    For locations with high requirements for bending performance, such as mobile phones and digital videos. 
    Note 
    1. Electrical Characteristics 
    Minimum insulation resistance (at 20℃): 1000 MΩ/km 
    Withstand Voltage: A.C. 1000V/1 min. 
    2. Marking: The wire with UL1609 has no markings.

     

    UL 
    STYLE NO.
    Insulation 
    Materials
    Rated (RATING)Conductor (tinned soft copper wire) CONDUCTOR 
    (Tinned Annealed Copper Wire)
    InsulatorApprox.
    weight 
    Reference weight 
    kg/km
    Maximum conductor resistance 
    MAX. 
    CONDUCTOR 
    RESISTANCE 
    (20℃) 
    (Ω / km)
    Dielectric withstand voltage 
    DIELECTRIC 
    STRENGTH 
    V(AC)/min
    Temperature 
    TEMP. 
    (℃)
    Voltage 
    VOLT 
    (V)
    SIZE 
    (AWG)
    constitute 
    N/mm
    Outer diameter 
    NAME. DAY 
    (mm)
    Insulation thickness NOM. THICK. (mm)Outer diameter 
    NOM. 
    DIA. 
    (mm)
    UL1609ETFE105125327/0.0800.240.150.540.635671000
    307/0.1020.300.150.600.86354
    287/0.1270.380.150.681.23223
    267/0.1600.480.150.781.79139
    247/0.2030.600.150.902.6786
    227/0.2540.780.151.084.1355
    207/0.3200.960.151.266.0235