- Description
-
Printed text:
AWM 21307 E237675 VW-1 80℃ 300V ( ) AWG RISHUN c
AWM I A/B FT1 80℃ 300V ( ) AWG LFInstructions
► Rated temperature: 80℃Rated voltage: 300V► Standards: UL758, UL1581► The conductor uses single-strand or stranded bare copper or tinned copper wire.►Polyethylene insulation► Flame-retardant polyethylene jacket► Uniform insulation thickness for easy stripping and cutting.►UL VW-1 and cUL FT1 flame-retardant testing passedApplication
1. Used for internal wiring in electronic devices2. Can replace UL2547No. Number of cores Conductor – conductor Insulation Wrap Shield Wrap-around shielding Drain wire – Drain line Braid Shield Jacket sheath Maximum Resistance at 20℃: Maximum conductor resistance Ω/km AWG No./mm line count/line diameter Nom.Dia. Outer diameter mm Nom. Thick. Thickness mm Nom.Dia. Outer diameter mm Construction structure No./mm line count/line diameter Gonstruction structure Jacket thickness mm Nom.Dia. Outer diameter mm 2 30 7/0.102 0.3 0.25 0.8 Al-mylar 7/0.102 16/4/0.10TD 0.5 3.1 354.33 28 7/0.102 0.38 0.26 0.9 Al-mylar 7/0.102 16/4/0.10TD 0.5 3.3 223.75 26 7/0.160 0.48 0.26 1 Al-mylar 7/0.160 16/5/0.10TD 0.5 3.5 139.76 24 11/0.160 0.61 0.25 1.1 Al-mylar 11/0.160 16/5/0.10TD 0.5 3.7 88.36 22 17/0.160 0.76 0.27 1.3 Al-mylar 17/0.160 16/6/0.10TD 0.5 4.1 60.16 3 30 7/0.102 0.3 0.25 0.8 Al-mylar 7/0.102 16/4/0.10TD 0.54 3.3 354.33 28 7/0.127 0.38 0.26 0.9 Al-mylar 7/0.127 16/5/0.10TD 0.53 3.5 223.75 26 7/0.160 0.48 0.26 1 Al-mylar 7/0.160 16/5/0.10TD 0.47 3.6 139.76 24 11/0/160 0.61 0.25 1.1 Al-mylar 11/0/160 16/5/0.10TD 0.52 3.9 88.36 22 17/0.160 0.76 0.27 1.3 Al-mylar 17/0.160 16/6/0.10TD 0.5 4.3 60.16 4 30 7/0.102 0.3 0.25 0.8 Al-mylar 7/0.102 16/4/0.10TD 0.54 3.5 354.33 28 7/0.127 0.38 0.26 0.9 Al-mylar 7/0.127 16/5/0.10TD 0.51 3.7 223.75 26 7/0.160 0.48 0.26 1 Al-mylar 7/0.160 16/6/0.10TD 0.54 4 139.76 24 11/0.160 0.61 0.25 1.1 Al-mylar 11/0.160 16/6/0.10TD 0.52 4.2 88.36 22 17/0.160 0.76 0.27 1.3 Al-mylar 17/0.160 16/7/0.10TD 0.58 4.8 60.16 5 30 7/0.102 0.3 0.25 0.8 Al-mylar 7/0.102 16/5/0.10TD 0.52 3.7 354.33 28 7/0.127 0.38 0.26 0.9 Al-mylar 7/0.127 16/6/0.10TD 0.54 4 223.75 26 7/0.160 0.48 0.26 1 Al-mylar 7/0.160 16/6/0.10TD 0.5 4.2 139.76 24 11/0.160 0.61 0.25 1.1 Al-mylar 11/0.160 16/7/0.10TD 0.52 4.5 88.36 22 17/0.160 0.76 0.27 1.3 Al-mylar 17/0.160 24/5/0.10TD 0.6 5.2 60.16 6 30 7/0.102 0.3 0.25 0.8 Al-mylar 7/0.102 16/6/0.10TD 0.55 4 354.33 28 7/0.127 0.38 0.26 0.9 Al-mylar 7/0.127 16/6/0.10TD 0.55 4.3 223.75 26 7/0.160 0.48 0.26 1 Al-mylar 7/0.160 16/6/0.10TD 0.55 4.6 139.76 24 11/0.160 0.61 0.25 1.1 Al-mylar 11/0.160 16/7/0.10TD 0.55 4.9 88.36 22 17/0.160 0.76 0.27 1.3 Al-mylar 17/0.160 24/6/0.10TD 0.6 5.6 60.16 7 30 7/0.102 0.3 0.25 0.8 Al-mylar 7/0.102 16/6/0.10TD 0.55 4 354.33 28 7/0.127 0.38 0.26 0.9 Al-mylar 7/0.127 16/6/0.10TD 0.55 4.3 223.75 26 7/0.160 0.48 0.26 1 Al-mylar 7/0.160 16/7/0.10TD 0.55 4.6 139.76 24 11/0.160 0.61 0.25 1.1 Al-mylar 11/0.160 16/7/0.10TD 0.55 4.9 88.36 22 17/0.160 0.76 0.27 1.3 Al-mylar 17/0.160 24/6/0.10TD 0.6 5.6 60.16
key word:
UL21307 Cable
Recommended Products
Consult now