• Description
  • Printed text:  + AWM 21307 E237675 VW-1 80℃ 300V ( ) AWG RISHUN c  ++ AWM I A/B FT1 80℃ 300V ( ) AWG LF

     

    Instructions

    ► Rated temperature: 80℃
     Rated voltage: 300V
    ► Standards: UL758, UL1581
    ► The conductor uses single-strand or stranded bare copper or tinned copper wire.
    ►Polyethylene insulation
    ► Flame-retardant polyethylene jacket
    ► Uniform insulation thickness for easy stripping and cutting.
    ►UL VW-1 and cUL FT1 flame-retardant testing passed

    Application

    1. Used for internal wiring in electronic devices
    2. Can replace UL2547

     

     

    No. Number of coresConductor – conductorInsulationWrap Shield Wrap-around shieldingDrain wire – Drain lineBraid ShieldJacket sheathMaximum Resistance at 20℃: Maximum conductor resistance Ω/km
    AWGNo./mm line count/line diameterNom.Dia. Outer diameter mmNom. Thick. Thickness mmNom.Dia. Outer diameter mmConstruction structureNo./mm line count/line diameterGonstruction structureJacket thickness mmNom.Dia. Outer diameter mm
    2307/0.1020.30.250.8Al-mylar7/0.10216/4/0.10TD0.53.1354.33
    287/0.1020.380.260.9Al-mylar7/0.10216/4/0.10TD0.53.3223.75
    267/0.1600.480.261Al-mylar7/0.16016/5/0.10TD0.53.5139.76
    2411/0.1600.610.251.1Al-mylar11/0.16016/5/0.10TD0.53.788.36
    2217/0.1600.760.271.3Al-mylar17/0.16016/6/0.10TD0.54.160.16
    3307/0.1020.30.250.8Al-mylar7/0.10216/4/0.10TD0.543.3354.33
    287/0.1270.380.260.9Al-mylar7/0.12716/5/0.10TD0.533.5223.75
    267/0.1600.480.261Al-mylar7/0.16016/5/0.10TD0.473.6139.76
    2411/0/1600.610.251.1Al-mylar11/0/16016/5/0.10TD0.523.988.36
    2217/0.1600.760.271.3Al-mylar17/0.16016/6/0.10TD0.54.360.16
    4307/0.1020.30.250.8Al-mylar7/0.10216/4/0.10TD0.543.5354.33
    287/0.1270.380.260.9Al-mylar7/0.12716/5/0.10TD0.513.7223.75
    267/0.1600.480.261Al-mylar7/0.16016/6/0.10TD0.544139.76
    2411/0.1600.610.251.1Al-mylar11/0.16016/6/0.10TD0.524.288.36
    2217/0.1600.760.271.3Al-mylar17/0.16016/7/0.10TD0.584.860.16
    5307/0.1020.30.250.8Al-mylar7/0.10216/5/0.10TD0.523.7354.33
    287/0.1270.380.260.9Al-mylar7/0.12716/6/0.10TD0.544223.75
    267/0.1600.480.261Al-mylar7/0.16016/6/0.10TD0.54.2139.76
    2411/0.1600.610.251.1Al-mylar11/0.16016/7/0.10TD0.524.588.36
    2217/0.1600.760.271.3Al-mylar17/0.16024/5/0.10TD0.65.260.16
    6307/0.1020.30.250.8Al-mylar7/0.10216/6/0.10TD0.554354.33
    287/0.1270.380.260.9Al-mylar7/0.12716/6/0.10TD0.554.3223.75
    267/0.1600.480.261Al-mylar7/0.16016/6/0.10TD0.554.6139.76
    2411/0.1600.610.251.1Al-mylar11/0.16016/7/0.10TD0.554.988.36
    2217/0.1600.760.271.3Al-mylar17/0.16024/6/0.10TD0.65.660.16
    7307/0.1020.30.250.8Al-mylar7/0.10216/6/0.10TD0.554354.33
    287/0.1270.380.260.9Al-mylar7/0.12716/6/0.10TD0.554.3223.75
    267/0.1600.480.261Al-mylar7/0.16016/7/0.10TD0.554.6139.76
    2411/0.1600.610.251.1Al-mylar11/0.16016/7/0.10TD0.554.988.36
    2217/0.1600.760.271.3Al-mylar17/0.16024/6/0.10TD0.65.660.16

     

key word:

UL21307 Cable

Consult now

* We will contact you within one business day. Please check your email.

Submit