- Description
-
Printed text:
AWM 2835 E237675 VW-1 60℃ 30V ( ) AWG RISHUN c
AWM I/ll A/B FT1 60℃ 30V ( ) AWG -F- LF Instructions
► Rated temperature: 60℃
Rated voltage: 30V
►Reference standards: UL758, UL1581
► Conductors shall be made of single-strand or stranded copper wire, 40 AWG or larger, tinned or bare.
►Polyvinyl chloride or semi-rigid polyvinyl chloride insulation
►Tinned or bare copper braided shielding
► PVC jacket
► Flame-retardant testing via ULVW-1, CULFT1, and JQAF-Mark
► Uses standard insulation thickness, easy-to-cut wire, and easy-to-strip wire.Application
For internal connecting wires in general electronic and electrical equipment.No.
Number of coresConductor
ConductorInsulation
InsulationWrap Shield
Twisted-pair shieldingDrain wire
Current drain lineBraid Shield Jacket
SheathMaximum Resistance at 20℃
Maximum conductor resistance
Ω/kmAWG
Wire gaugeNo./mm
Number of wires / Wire diameterNom.Dia.
Outer diameter
mmNom.Thick.
Thickness
mmNom.Dia.
Outer diameter mmConstruction
StructureNo./mm
Number of wires / Wire diameterConstruction
StructureSheath thickness
Jacket
Thickness
mmNom.
Day.
Outer diameter
mm2 30 7/0.102 0.30 0.25 0.80 Al-mylar 7/0.102 16/4/0.10TD 0.50 3.10 354.33 28 7/0.102 0.38 0.26 0.90 Al-mylar 7/0.102 16/4/0.10TD 0.50 3.30 223.75 26 7/0.160 0.48 0.26 1.00 Al-mylar 7/0.160 16/5/0.10TD 0.50 3.50 139.76 24 11/0.160 0.61 0.25 1.10 Al-mylar 11/0.160 16/5/0.10TD 0.50 3.70 88.36 22 17/0.160 0.76 0.27 1.30 Al-mylar 17/0.160 16/6/0.10TD 0.50 4.10 60.16 3 30 7/0.102 0.30 0.25 0.80 Al-mylar 7/0.102 16/4/0.10TD 0.54 3.30 354.33 28 7/0.127 0.38 0.26 0.90 Al-mylar 7/0.127 16/5/0.10TD 0.53 3.50 223.75 26 7/0.160 0.48 0.26 1.00 Al-mylar 7/0.160 16/5/0.10TD 0.47 3.60 139.76 24 11/0/160 0.61 0.25 1.10 Al-mylar 11/0/160 16/5/0.10TD 0.52 3.90 88.36 22 17/0.160 0.76 0.27 1.30 Al-mylar 17/0.160 16/6/0.10TD 0.50 4.30 60.16 4 30 7/0.102 0.30 0.25 0.80 Al-mylar 7/0.102 16/4/0.10TD 0.54 3.50 354.33 28 7/0.127 0.38 0.26 0.90 Al-mylar 7/0.127 16/5/0.10TD 0.51 3.70 223.75 26 7/0.160 0.48 0.26 1.00 Al-mylar 7/0.160 16/6/0.10TD 0.54 4.00 139.76 24 11/0.160 0.61 0.25 1.10 Al-mylar 11/0.160 16/6/0.10TD 0.52 4.20 88.36 22 17/0.160 0.76 0.27 1.30 Al-mylar 17/0.160 16/7/0.10TD 0.58 4.80 60.16 5 30 7/0.102 0.30 0.25 0.80 Al-mylar 7/0.102 16/5/0.10TD 0.52 3.70 354.33 28 7/0.127 0.38 0.26 0.90 Al-mylar 7/0.127 16/6/0.10TD 0.54 4.00 223.75 26 7/0.160 0.48 0.26 1.00 Al-mylar 7/0.160 16/6/0.10TD 0.50 4.20 139.76 24 11/0.160 0.61 0.25 1.10 Al-mylar 11/0.160 16/7/0.10TD 0.52 4.50 88.36 22 17/0.160 0.76 0.27 1.30 Al-mylar 17/0.160 24/5/0.10TD 0.60 5.20 60.16 6 30 7/0.102 0.30 0.25 0.80 Al-mylar 7/0.102 16/6/0.10TD 0.55 4.00 354.33 28 7/0.127 0.38 0.26 0.90 Al-mylar 7/0.127 16/6/0.10TD 0.55 4.30 223.75 26 7/0.160 0.48 0.26 1.00 Al-mylar 7/0.160 16/6/0.10TD 0.55 4.60 139.76 24 11/0.160 0.61 0.25 1.10 Al-mylar 11/0.160 16/7/0.10TD 0.55 4.90 88.36 22 17/0.160 0.76 0.27 1.30 Al-mylar 17/0.160 24/6/0.10TD 0.60 5.60 60.16 7 30 7/0.102 0.30 0.25 0.80 Al-mylar 7/0.102 16/6/0.10TD 0.55 4.00 354.33 28 7/0.127 0.38 0.26 0.90 Al-mylar 7/0.127 16/6/0.10TD 0.55 4.30 223.75 26 7/0.160 0.48 0.26 1.00 Al-mylar 7/0.160 16/7/0.10TD 0.55 4.60 139.76 24 11/0.160 0.61 0.25 1.10 Al-mylar 11/0.160 16/7/0.10TD 0.55 4.90 88.36 22 17/0.160 0.76 0.27 1.30 Al-mylar 17/0.160 24/6/0.10TD 0.60 5.60 60.16
key word:
UL2835 Insulated Wire
Recommended Products