• Description
  • Printed text: 77 AWM 2468 E237675 VW-1 80℃ 300V ( ) AWG RISHUN c 111 AWM I A FT1 80℃ 300V ( ) AWG -F- LF

     

    Instructions
    ► Rated temperature: 80℃
    Rated voltage: 300V
    ► Standards: UL758, UL1581
    ► The conductor shall use single-strand or stranded bare copper or tinned copper wire with a gauge of 32-16 AWG or higher.
    ►Polyvinyl chloride insulation
    ► Uniform insulation thickness for easy stripping and cutting.
    ► Bare copper or tinned copper wire twisted or braided to achieve a shielding rate of 95%
    ►Passed UL VW-1, cUL FT1, and JQA F-Mark flame-retardant tests

     
    Application
    For internal wiring in electrical and computer equipment

     

    Part No.
    Model
    Conductor
    Conductor
    Pitch
    Spacing
    (mm)
    Cores
    Number of cores
    Insulation Thick
    Insulation thickness
    (mm)
    Dia.
    Outer diameter
    (mm)
    Maximum Resistance at 20℃
    Maximum conductor resistance
    Ω/km
    AWG
    Wire gauge
    Construction
    Structure
    UL2468 26 7 divided by 0.16 1.5 2 0.45 1.4 × 2.9 139.76
    3 1.4 × 4.4
    4 1.4 × 5.9
    5 1.4 × 7.4
    6 1.4 × 8.9
    7 1.4 × 10.4
    8 1.4 × 11.9
    9 1.4 × 13.4
    10 1.4 × 14.9
    11 1.4 × 16.4
    12 1.4 × 17.9
    13 1.4 × 19.4
    14 1.4 × 20.9
    15 1.4 × 22.4
    16 1.4 × 23.9
    17 1.4 × 25.4
    18 1.4 × 26.9
    UL2468 24 7/0.20 11/0.16 1.6 2 0.45 1.5 × 3.1 88.36
    3 1.5 × 4.7
    4 1.5 × 6.3
    5 1.5 × 7.9
    6 1.5 × 9.5
    7 1.5 × 11.1
    8 1.5 × 12.7
    9 1.5 × 14.3
    10 1.5 × 15.9
    11 1.5 × 17.5
    12 1.5 × 19.1
    13 1.5 × 20.7
    14 1.5 × 22.3
    15 1.5 × 23.9
    16 1.5 × 25.5
    17 1.5 × 27.1
    18 1.5 × 28.7
    UL2468 22 7/0.254 17/0.16 1.8 2 0.45 1.7 × 3.5 60.16
    3 1.7 × 5.3
    4 1.7 × 7.1
    5 1.7 × 8.9
    6 1.7 × 10.7
    7 1.7 × 12.5
    8 1.7 × 14.3
    9 1.7 × 16.1
    10 1.7 × 17.9
    11 1.7 × 19.7
    12 1.7 × 21.5
    13 1.7 × 23.3
    14 1.7 × 25.1
    15 1.7 × 26.9
    16 1.7 × 28.7
    17 1.7 × 30.5
    18 1.7 × 32.3
    UL2468 26 7 divided by 0.16 1.5 2 0.45 1.4 × 2.9 139.76
    3 1.4 × 4.4
    4 1.4 × 5.9
    5 1.4 × 7.4
    6 1.4 × 8.9
    7 1.4 × 10.4
    8 1.4 × 11.9
    9 1.4 × 13.4
    10 1.4 × 14.9
    11 1.4 × 16.4
    12 1.4 × 17.9
    13 1.4 × 19.4
    14 1.4 × 20.9
    15 1.4 × 22.4
    16 1.4 × 23.9
    17 1.4 × 25.4
    18 1.4 × 26.9
    UL2468 24 7/0.20 11/0.16 1.6 2 0.45 1.5 × 3.1 88.36
    3 1.5 × 4.7
    4 1.5 × 6.3
    5 1.5 × 7.9
    6 1.5 × 9.5
    7 1.5 × 11.1
    8 1.5 × 12.7
    9 1.5 × 14.3
    10 1.5 × 15.9
    11 1.5 × 17.5
    12 1.5 × 19.1
    13 1.5 × 20.7
    14 1.5 × 22.3
    15 1.5 × 23.9
    16 1.5 × 25.5
    17 1.5 × 27.1
    18 1.5 × 28.7
    UL2468 22 7/0.254 17/0.16 1.8 2 0.45 1.7 × 3.5 60.16
    3 1.7 × 5.3
    4 1.7 × 7.1
    5 1.7 × 8.9
    6 1.7 × 10.7
    7 1.7 × 12.5
    8 1.7 × 14.3
    9 1.7 × 16.1
    10 1.7 × 17.9
    11 1.7 × 19.7
    12 1.7 × 21.5
    13 1.7 × 23.3
    14 1.7 × 25.1
    15 1.7 × 26.9
    16 1.7 × 28.7
    17 1.7 × 30.5
    18 1.7 × 32.3

     

key word:

UL2468 Insulated Wire

Consult now

* We will contact you within one business day. Please check your email.