• Description
  • Printed text: 555 AWM 2464 E237675 VW-1 80℃ 300V ( ) AWG RISHUN c 555 AWM II A/B FT1 80℃ 300V ( ) AWG -F- LF

     

    Instructions
    ► Rated temperature: 80℃
    ► Rated voltage: 300V
    ► Standards: UL758, UL1581
    ► The conductor uses single-strand or stranded bare copper or tinned copper wire.
    ►Polyvinyl chloride insulation
    ►After the core wires are bundled together, they are shielded by an aluminum foil Mylar tape.
    ► Bare copper or bare copper wire stranded ground wire
    ► Bare copper or tinned copper wire twisted or braided to achieve a shielding rate of 95%
    ►Polyvinyl chloride jacket
    ► Flame-retardant testing via ULVW-1, CULFT1, and JQAF-Mark

     
    Application
    For internal and external wiring in electronic devices

     

    Part No.
    Model
    Conductor
    Conductor
    Cores
    Core wire
    Insulation Thick
    Insulation thickness
    (mm)
    Wrap-around layer Braild
    Weaving
    Jacket
    Sheath
    Maximum Resistance at 20℃
    Maximum conductor resistance
    Ω/km
    AWG
    Line number
    Construction
    Structure
    material
    Materials
    Construction
    Structure
    Thick.
    Standard thickness
    (mm)
    Dia.
    (mm)
    UL2464 26 7 divided by 0.16 2 0.25 Aluminum foil
    Al-Myiar

    16/4/0.10

    0.80 4.15 139.76
    3

    16/4/0.10

    4.30
    4

    16/5/0.10

    4.55
    5

    16/5/0.10

    4.85
    6

    16/6/0.10

    5.15
    7

    16/6/0.10

    5.20
    8

    16/6/0.10

    5.50
    9

    16/7/0.10

    5.90
    10

    16/8/0.10

    6.20
    UL2464 24   11/0.16 2 0.25   Aluminum foil
    Al-Myiar

    16/4/0.10

    0.80   4.35 88.36  
    3

    16/4/0.10

    4.50
    4

    16/5/0.10

    4.80
    5

    16/6/0.10

    5.10
    6

    16/6/0.10

    5.45
    7

    16/6/0.10

    5.50
    8

    16/7/0.10

    5.80
    9

    16/8/0.10

    6.20
    10

    24/6/0.10

    6.60
    UL2464 22 17/0.16 2 0.25 Aluminum foil
    Al-Myiar

    16/5/0.10

    0.80 4.75 60.16
    3

    16/6/0.10

    4.95
    4

    16/6/0.10

    5.30
    5

    16/7/0.10

    5.65
    6

    16/8/0.10

    6.05
    7

    16/8/0.10

    6.10
    8

    16/8/0.10

    6.50
    9

    24/6/0.10

    7.00
    10

    24/7/0.10

    7.40
    UL2464 20 21/0.178 2 0.25 Aluminum foil
    Al-Myiar

    16/6/0.10

    0.80 5.15 38.58
    3

    16/6/0.10

    5.40
    4

    16/7/0.10

    5.75
    5

    16/8/0.10

    6.20
    6

    24/6/0.10

    6.65
    7

    24/6/0.10

    6.70
    8

    24/6/0.10

    7.10
    9

    24/7/0.10

    7.70
    10

    24/8/0.10

    8.20
    UL2464 18 34/0.178 2 0.25 Aluminum foil
    Al-Myiar

    16/8/0.10

    0.80 5.75 22.98
    3

    24/6/0.10

    6.00
    4

    24/6/0.10

    6.50
    5

    24/7/0.10

    7.00
    6

    24/8/0.10

    7.55
    7

    24/8/0.10

    7.60
    8

    24/7/0.12

    8.20
    9

    24/8/0.12

    8.90
    10

    24/9/0.12

    9.50

key word:

UL2464 Insulated Wire

Consult now

* We will contact you within one business day. Please check your email.