• Description
  • Printed text: 55 AWM 2464 E237675 VW-1 80℃ 300V ( ) AWG RISHUN c 666 AWM II A/B FTI 80℃ 300V ( ) AWG -F- LF

     

    Instructions
    ► Rated temperature: 80℃
    ► Rated voltage: 300V
    ► Standards: UL758, UL1581
    ► The conductor uses single-strand or stranded bare copper or tinned copper wire.
    ►Polyvinyl chloride insulation
    ► After the core wires are bundled, they are wrapped in aluminum foil Mylar.
    ► Bare copper or bare copper wire stranded ground wire
    ► Bare copper or tinned copper wire winding
    ►Polyvinyl chloride jacket
    ► Flame-retardant testing via ULVW-1, CULFT1, and JQAF-Mark

     
    Application
    For internal and external wiring in electronic devices

     

    Part No.
    Model
    Conductor
    Conductor
    Cores
    Core wire
    Insulation Thick
    Insulation thickness
    (mm)
    Wrap-around layer Braild
    Weaving
    Jacket
    Sheath
    Maximum Resistance at 20℃
    Maximum conductor resistance
    Ω/km
    AWG
    Line number
    Construction
    Structure
    material
    Materials
    Construction
    Structure
    Thick.
    Standard thickness
    (mm)
    Dia.
    (mm)
    UL2464 26 7/0.160 2 0.25 Aluminum foil
    Al-Myiar
    / 0.80

    3.75

    139.76
    3 /

    3.90

    4 /

    4.15

    5 /

    4.45

    6 /

    4.75

    7 /

    4.80

    8 /

    5.10

    9 /

    5.50

    10 /

    5.80

    UL2464 24   11/0.160 2 0.25   Aluminum foil
    Al-Myiar
    / 0.80  

    3.95

    88.36  
    3 /

    4.10

    4 /

    4.40

    5 /

    4.70

    6 /

    5.05

    7 /

    5.10

    8 /

    5.40

    9 /

    5.80

    10 /

    6.20

    UL2464 22 17/0.160 2 0.25 Aluminum foil
    Al-Myiar
    / 0.80

    4.35

    60.16
    3 /

    4.55

    4 /

    4.90

    5 /

    5.25

    6 /

    5.65

    7 /

    5.70

    8 /

    6.10

    9 /

    6.60

    10 /

    7.00

    UL2464 20 21/0.178 2 0.25 Aluminum foil
    Al-Myiar
    / 0.80

    4.75

    38.58
    3 /

    5.00

    4 /

    5.35

    5 /

    5.80

    6 /

    6.25

    7 /

    6.30

    8 /

    6.70

    9 /

    7.30

    10 /

    7.80

    UL2464 18 34/0.178 2 0.25 Aluminum foil
    Al-Myiar
    / 0.80

    5.35

    22.98
    3 /

    5.60

    4 /

    6.10

    5 /

    6.60

    6 /

    7.15

    7 /

    7.20

    8 /

    7.80

    9 /

    8.50

    10 /

    9.10

key word:

UL2464 Insulated Wire

Consult now

* We will contact you within one business day. Please check your email.