AWM 1618 E237675 VW-1 80℃ 300V ( ) AWG RISHUN c
AWM I A/B FT1 80℃ 300V ( ) AWG -F- LF Instructions
► Rated temperature: 80℃
Rated voltage: 300V
► Standards: UL758, UL1581
► The conductor uses 16-28 AWG single-strand or stranded bare copper or tinned copper wire.
►Sheath thickness: 5 to 50 mils (0.127 to 1.016 mm)
► Uniform insulation thickness for easy stripping and cutting.
► Flame-retardant testing via ULVW-1, CULFT1, and JQAF-MarkApplication
For internal wiring in electronic devicesPart No.
ModelConductor
ConductorInsulation
InsulationMaximum Resistance at 20℃
Maximum conductor resistance
Ω/kmAWG
Wire gaugeNO./mm
Number of wires / Wire diameterDia.
Outer diameter
mmPrimary Nom. Thick.
Insulation thickness
mmSecondary Nom. Thick.
Insulation thickness
mmNom.Dia.
Outer diameter
mmUL1618 28 7/0.127 0.38 0.41 0.40 2.00 223.75 UL1618 26 7/0.160 0.48 0.41 0.40 2.10 139.75 UL1618 24 11/0.160 0.61 0.41 0.40 2.20 88.36 UL1618 22 17/0.160 0.76 0.41 0.40 2.40 60.16 UL1618 20 21/0.178 0.94 0.41 0.40 2.60 38.58 UL1618 18 34/0.178 1.20 0.41 0.40 2.80 22.98 UL1618 16 26/0.254 1.50 0.41 0.40 3.10 15.06