• Description
  • Printed text: 444 AWM 1569 E237675 VW-1 105℃ 300V ( ) AWG RISHUN c 111 AWM I A FT1 105℃ 300V ( ) AWG -F- LF

     

    Instructions
    ► Rated temperature: 105℃
    Rated voltage: 300V
    ► Standards: UL758, UL1581
    ► The conductor uses 30- to 16-AWG single-strand or stranded bare copper or tinned copper wire.
    ►Polyvinyl chloride insulation
    ► Uniform insulation thickness for easy stripping and cutting.
    ►Passed ULVW-1, CULFT1, and JQAF-Mark flame-retardant tests

     
    Application
    For internal wiring in electronic and electrical equipment

        

    Part No.
    Model
    Conductor
    Conductor
    Insulation
    Insulation
    Maximum Resistance at 20℃
    Maximum conductor resistance
    Ω/km
    AWG
    Wire gauge
    NO./mm
    Number of threads / Thread diameter
    Dia.
    Outer diameter
    mm
    Nom.Thick.
    Insulation thickness
    mm
    Nom.Dia.
    Outer diameter
    mm
    UL1569 30 7/0.102 0.30 0.41 1.10 354.33
    UL1569 28 7/0.127 0.38 0.41 1.20 223.75
    UL1569 26 7/0.160 0.48 0.41 1.30 139.76
    UL1569 24 11/0.160 0.61 0.41 1.40 88.36
    UL1569 22 17/0.160 0.76 0.41 1.60 60.16
    UL1569 20 21/0.178 0.94 0.41 1.80 38.58
    UL1569 18 34/0.178 1.20 0.41 2.10 22.98
    UL1569 16 26/0.254 1.50 0.41 2.40 15.06

     

key word:

UL1569 Insulated Wire

Consult now

* We will contact you within one business day. Please check your email.

Submit