• Description
  • Printed text: 444 AWM 1283 E237675 VW-1 105℃ 600V ( ) AWG RISHUN c 444 AWM I A FT1 105℃ 600V ( ) AWG -F- LF

     

    Instructions

    ► Rated temperature: 105℃
    Rated voltage: 600V
    ► Standards: UL758, UL1581
    ► The conductor uses 8-2 AWG solid or stranded bare copper or tinned copper wire.
    ►Polyvinyl chloride insulation
    ► Uniform insulation thickness for easy stripping and cutting.
    ► Flame-retardant testing via ULVW-1, CULFT1, and JQAF-Mark

    Application
    For internal wiring in electronic and electrical equipment

     

     

    Part No.
    Model
    Conductor
    Conductor
    Insulation
    Insulation
    Maximum Resistance at 20℃
    Maximum conductor resistance
    Ω/km
    AWG wire gauge NO./mm
    Number of wires / Wire diameter
    Nom.Dia.
    Outer diameter
    mm
    Nom.Thick.
    Insulation thickness
    mm
    Nom.Dia.
    Outer diameter
    mm
    UL1283 8 7/24/0.254 4.31 1.64 7.59 2.37
    UL1283 6 7/38/0.254 5.45 1.64 8.73 1.49
    UL1283 4 7/60/0.254 6.81 1.64 10.09 0.947
    UL1283 2 19/35/0.254 8.67 1.64 11.95 0.600

     

key word:

UL1283 Insulated Wire

Consult now

* We will contact you within one business day. Please check your email.

Submit